Top 10 Ge Capacitor Cbb65s

0
672 reviews analysed

1. MAXRUN 45+5 MFD uf 370 or 440 Volt VAC Round Motor Dual Run Capacitor for AC Air Conditioner Condenser – 45/5 uf MFD 440V Straight Cool or Heat Pump – Will Run AC Motor and Fan – 1 Year Warranty

MAXRUN 45+5 MFD uf 370 or 440 Volt VAC Round Motor Dual Run Capacitor for AC Air Conditioner Condenser - 45/5 uf MFD 440V Straight Cool or Heat Pump - Will Run AC Motor and Fan - 1 Year Warranty

Feature

2. MAXRUN 40+5 MFD uf 370 or 440 Volt VAC Round Motor Dual Run Capacitor for AC Air Conditioner Condenser – 40/5 uf MFD 440V Straight Cool or Heat Pump – Will Run AC Motor and Fan – 1 Year Warranty

MAXRUN 40+5 MFD uf 370 or 440 Volt VAC Round Motor Dual Run Capacitor for AC Air Conditioner Condenser - 40/5 uf MFD 440V Straight Cool or Heat Pump - Will Run AC Motor and Fan - 1 Year Warranty

Feature

3. MAXRUN 60+5 MFD uf 370 or 440 Volt VAC Round Motor Dual Run Capacitor for AC Air Conditioner Condenser – 55/5 uf MFD 440V Straight Cool or Heat Pump – Will Run AC Motor and Fan – 5 Year Warranty

MAXRUN 60+5 MFD uf 370 or 440 Volt VAC Round Motor Dual Run Capacitor for AC Air Conditioner Condenser - 55/5 uf MFD 440V Straight Cool or Heat Pump - Will Run AC Motor and Fan - 5 Year Warranty

Feature

4. MAXRUN 50+5 MFD uf 370 or 440 Volt VAC Round Motor Dual Run Capacitor for AC Air Conditioner Condenser – 50/5 uf MFD 440V Straight Cool or Heat Pump – Will Run AC Motor and Fan – 5 Year Warranty

MAXRUN 50+5 MFD uf 370 or 440 Volt VAC Round Motor Dual Run Capacitor for AC Air Conditioner Condenser - 50/5 uf MFD 440V Straight Cool or Heat Pump - Will Run AC Motor and Fan - 5 Year Warranty

Feature

5. MAXRUN 55+5 MFD uf 370 or 440 Volt VAC Round Motor Dual Run Capacitor for AC Air Conditioner Condenser – 55/5 uf MFD 440V Straight Cool or Heat Pump – Will Run AC Motor and Fan – 1 Year Warranty

MAXRUN 55+5 MFD uf 370 or 440 Volt VAC Round Motor Dual Run Capacitor for AC Air Conditioner Condenser - 55/5 uf MFD 440V Straight Cool or Heat Pump - Will Run AC Motor and Fan - 1 Year Warranty

Feature

6. PowerWell 50 MFD uf Motor Run Round Capacitor 370 V VAC or 440 Volt 50 Micro Farad PW-50/R – Guaranteed to Last 5 Years

PowerWell 50 MFD uf Motor Run Round Capacitor 370 V VAC or 440 Volt 50 Micro Farad PW-50/R - Guaranteed to Last 5 Years

Feature

Description

A capacitor is an electric component that temporarily stores an electrical charge. A “run capacitor” is used to boost the starting torque and efficiency on electric motors or compressor.

Round capacitors come in a variety of sizes, depending on the capacitance (µF = MFD = micro farad), such as 50 µF, and also the voltage. A 440 volt capacitor can be used in place of a 370 volt, as it is build better, but the 370 can’t be used in place of a 440 volt. It will work for a while and will fail prematurely, as exceeding the capacitor’s rated voltage will cause the dielectric to break down and the capacitor to short out. It is like a Ferrari that can do 440 miles per hour, driving on a road that have speed limit of 370 m/h. The capacitance(µF or MFD or micro farad) must be the same or stay within 10%+ or 5%- of its original value . Example: 50 µF cap can be substituted by 48 – 55 MFD with the same or better voltage ratings capacitor.

If your motor or fan is not able to start, or the capacitor is bulged on top most likely your capacitor is defective. Round capacitor can be used to substitute oval shape one with the same MFD AND Volt specs.

You will ask “Why I need a Cap that is rated 440V in my A/C?”

Answer: You need to realize that a motor is an inductive device. When the supply voltage is applied to the motor run winding, the voltage across the start winding will be increased to a higher voltage value. A motor acts like a transformer with the run winding acting as the primary and the start winding acting as the secondary. This is why the capacitor has a much higher voltage rating than the 230 being the supply voltage.

If a Capacitor is not EIA-456-A approved means it is NOT approved for USA market.

7. QH QX6530 Capacitor Motor Run Round 30 uF MFD 370V HVAC

QH QX6530 Capacitor Motor Run Round 30 uF MFD 370V HVAC

Feature

8. BOJACK Motor and Fan Starting Round Capacitor 30 uf MFD 370V 450VAC 50/60Hz CBB65 10000AFC

BOJACK Motor and Fan Starting Round Capacitor 30 uf MFD 370V 450VAC 50/60Hz CBB65 10000AFC

Feature

Description

This capacitor is used for start-up and operation of AC motors with frequency of 50Hz/60Hz such as air conditioners, compressors and motors. It is small in size, lightweight, heat resisting and anti-explosion.

Round capacitor can be used to substitute oval shape one with the same MFD AND Volt specs.

A 440 volt capacitor can be used in place of a 370 volt, as it is build better, but the 370 can’t be used in place of a 440 volt.

Model: CBB65(Universal model)
Shell material: metal
Dielectric Material: metallized polypropylene film
Capacity: 30uf
Tolerance: ±5%
Rated voltage: 450V AC
Frequency: 50 / 60Hz

9. PowerWell 50 + 5 MFD uf PW-50/5/R 370 or 440 Volt Dual Run Round Capacitor for Condenser Straight Cool or Heat Pump Air Conditioner 50/5 Micro Farad – Guaranteed to Last 5 Years

PowerWell 50 + 5 MFD uf PW-50/5/R 370 or 440 Volt Dual Run Round Capacitor for Condenser Straight Cool or Heat Pump Air Conditioner 50/5 Micro Farad - Guaranteed to Last 5 Years

Feature

Description

A capacitor is an electric component that temporarily stores an electrical charge. A dual “run capacitor” supports two electric motors, such as a fan motor and a compressor. Round dual run capacitors are used to start and run the unit more efficient. It saves space by combining two physical capacitors into one case. The dual capacitor has three terminals labeled “C”, “FAN”, and “HERM”, which stand for the *C*ommon, Fan, and *HERM*etically sealed compressor.

Dual capacitors come in a variety of sizes, depending on the capacitance (µF = MFD = micro farad), such as 60 plus 5 µF, and also the voltage. A 440 volt capacitor can be used in place of a 370 volt, as it is build better, but the 370 can’t be used in place of a 440 volt. It will work for a while and will fail prematurely, as exceeding the capacitor’s rated voltage will cause the dielectric to break down and the capacitor to short out. Same as an electric wire- 600V rated wire is better than 300V one .The capacitance(µF or MFD or micro farad) must be the same or stay within 10%+ or 5%- of its original value . Example: 50 µF cap can be substituted by 48 – 55 MFD with the same or better voltage ratings capacitor.

If your fan is working but compressor not, or the capacitor is bulged on top most likely your capacitor is defective. Round capacitor can be used to substitute oval shape one with the same MFD AND Volt specs.

You will ask “Why I need a Cap that is rated 440V in my A/C?”

Answer: You need to realize that a motor is an inductive device. When the supply voltage is applied to the motor run winding, the voltage across the start winding will be increased to a higher voltage value. A motor acts like a transformer with the run winding acting as the primary and the start winding acting as the secondary. This is why the capacitor has a much higher voltage rating than the 230 being the supply voltage.

If a Capacitor is not EIA-456-A approved means it is NOT approved for USA market.

10. QX6550 Capacitor Motor Run Round 50 uF MFD 370 V VAC Volt HVAC

QX6550 Capacitor Motor Run Round 50 uF MFD 370 V VAC Volt HVAC

Feature

Description

. 50 uF MFD 370V . CBB65 . 50/60Hz Product Size: 2”x2”x5” G.W: 8oz

Conclusion

By our suggestions above, we hope that you can found Ge Capacitor Cbb65s for you.Please don’t forget to share your experience by comment in this post. Thank you!

Home Previews
Logo
Enable registration in settings - general